Detailed Project Report on polycrystalline solar pv module
- More than 40 years of experience
- Managed by expert industrial consultants
- ISO 9001-2015 Certified
- Registered under MSME, UAM No: DL01E0012000
- 24/5 Research Support
Get your quesries resolved from an industry expert. Ask your queries before report or book purchase. - Custom Research Service
Speak to the our consultant to design an exclusive study to serve your research needs. - Quality Assurance
All reports are prepared by highly qualified consultants & verified by a panel of experts. - Information Security
Your personal & confidential information is safe & secure.
POLYCRYSTALLINE SOLAR PV MODULE
[CODE NO.4303]
The power generated by a single cell is small and therefore several cells are interconnected in series/parallel combination to get the required voltage and current. When a number of solar cells are connected in series to get a specific voltage the unit so formed is called as Solar Module. Charging batteries is the primary use of SPV module. Therefore normally 36 cells are joined in series to form a standard module, which is capable of charging 12 volts battery
CONSTRUCTION OF PV MODULE
Solar photovoltaic or ‘PV’ panels are made using the 6 main components described below and assembled in advanced manufacturing facilities with extreme accuracy. In this article we will focus on panels made using silicon crystalline solar cells which are by far the most common and highest performing solar technology available today. There are other solar PV technologies available such as thin film and screen printed cells but we will not be discussing these as they have limited use or are still in development.
The 6 Main components of a solar panel
• Extruded Aluminium frame
• Tempered Glass - 3 to 4mm thick
• Silicon PV cells
• Encapsulation - EVA film layers
• Polymer rear backsheet
• Junction box - diodes and connectors
Many well known solar panel manufacturers are ‘vertically integrated’ which means the one company supplies and manufactures all the main components including the silicon ingots and wafers used to make the solar PV cells. However many panel manufacturers assemble solar panels using externally sourced parts including cells, polymer back sheet and encapsulation EVA material. These manufacturers can be more selective about which components they chose but they do not always have control over the quality of the products so they should be sure they use the best suppliers available.
PV Cells
A Monocrystalline solar cell (click to enlarge)
Silicon photovoltaic cells or PV cells convert sunlight directly into DC electrical energy. The performance of the solar panel is determined by the cell type and characteristics of the silicon used, with the two main types being monocrystallineand polycrystalline silicon. Additionally the base of the cell can be built using different additives to create either a positive p-type silicon or negative n-type silicon. However there are several different cell configurations available which offer different levels of efficiency and performance. See more information in the complete solar PV technology review.
Most residential solar panels contain 60 cells linked together via busbars in series to generate a voltage between 30-40 volts depending on the type of cell used. Larger solar panels used for commercial systems and utility scale solar farms contain 72 or even 90 cells and in turn operate at a higher voltage. The electrical contacts which interconnect the cells are known as busbarsand allow the current to flow through all the cells in a circuit.
Basic construction diagram of a common (P-type) silicon solar cell.
Glass
The front glass sheet protects the PV cells from the weather and impact from hail or airborne debris. The glass is typically high strength tempered glass which is 3.0 to 4.0mm thick and is designed resist mechanical loads and extreme temperature changes. The IEC minimum standard impact test requires solar panels to withstand an impact of hail stones of 1 inch (25 mm) diameter traveling up to 60 mph (27 m/s). In the event of an accident or severe impact tempered glass is also much safer than standard glass as it shatters into tiny fragments rather than sharp jagged sections.
To improve efficiency and performance high transmissive glass is used by most manufacturers which has a very low iron content and an anti-reflective coating on the rear side to reduce losses and improve light transmission.
Frame
The aluminium frame plays a critical role by both protecting the edge of the laminate section housing the cells and providing a solid structure to mount the solar panel in position. The extruded aluminium sections are designed to be extremely lightweight, stiff and able to withstand extreme stress and loading from high wind and external forces.
The aluminium frame can be silver or anodised black and depending on the panel manufacturer the corner sections can either be screwed, pressed or clamped together providing different levels of strength and stiffness.
EVA Film
EVA stands for ‘ethylene vinyl acetate’ which is a specially designed polymer highly transparent (plastic) layer used to encapsulate the cells and hold them in position during manufacture. The EVA material must be extremely durable and tolerant of extreme temperature and humidity, it plays an important part in the long term performance by preventing moisture and dirt ingress.
The lamination either side of the PV cells provides some shock absorption and helps protect the cells and interconnecting wires from vibrations and sudden impact from hail stones and other objects. A high quality EVA film with a high degree of what is known as ‘cross-linking’ can be the difference between a long life or a panel failure due to water ingress. During manufacture the cells are first encapsulated with the EVA before being assembled within the glass and back sheet.
Backsheet
The backsheet is the rear most layer of common solar panels which as acts as a moisture barrier and final external skin to provide both mechanical protection and electrical insulation. The backsheet material is made of various polymers or plastics including PP, PET and PVF which offer different levels of protection, thermal stability and long term UV resistance. The backsheet layer is typically white in colour but is also available as clear or black depending on the manufacturer and module.
‘Tedlar’ PVF material from Dupont is known as one the leading high performance back sheets for PV module manufacturing.
Dual glass panels - Some panels such as bifacial and frameless panels use a rear glass panel instead of a polymer backsheet. The rear side glass is more durable and longer lasting than most backsheet materials and so some manufacturers offer a 30 year performance warranty on dual glass panels.
Junction Box
The junction box is a small weather proof enclosure located near the top on the rear side of the panel. It is needed to securely attach the cables required to interconnect the panels. The junction box is important as it is the central point where all the cells sets interconnect and must be protected from moisture and dirt.
Bypass diodes
The junction box also houses the bypass diodes which are needed to prevent back current which occurs when some cells are shaded or dirty. Diodes only allow current to flow in one direction and a typical 60 cell panel has 3 rows of 20 PV cells and in turn there are 3 bypass diodes, one for preventing reverse current to each of the 3 sets of cells. Unfortunately bypass diodes can fail over time and may need to be replaced, so the cover of the junction box is usually able to be removed for servicing, although many modern solar panels now use more advanced long lasting diodes and non-serviceable junction boxes.
Number of Cells in Module
Number of cells in a module depends upon the standard voltage requirement per module. In 1980’s solar modules were mainly manufactured for charging 12 Volt batteries. But for charging a 12 Volt battery it is required to have sufficiently higher output voltage of the module than 12 Volt. It was standard practice to design a solar module with maximum voltage rating (Vm) of 15 Volt. This module of 15 Volt becomes standard module from those days.
The number of solar cells to be connected in series to achieve standard voltage output depends upon the open-circuit voltage (Voc) of the individual cells. The Voc of a solar cell depends upon mainly its manufacturing techniques. The table below shows the open-circuit voltage of different solar cells at standard test conditions.
Solar Cell Types Open Circuit Voltage at STC
Mono Crystalline Silicon Solar Cell 0.55 to 0.68 V
Poly Crystalline Silicon Solar Cell 0.55 to 0.65 V
Amorphous Silicon Solar Cell 0.7 to 1.1 V
Cadmium Telluride Solar Cell 0.8 to 1.0 V
Copper Indium Gallium Selenide Solar Cell 0.5 to 0.7 V
Gallium Indium Phosphide/ Gallium Arsenide / Gallium Solar Cell 1 to 2.5 V
For a crystalline solar cell the open-circuit voltage, is about 0.5 V, as shown in the table above. The voltage Voc is mentioned at 25oC but at the temperature higher than 25oC the value of this voltage drops nearly by 0.08 V.
So at normal operating temperature the voltage available across the terminals of each crystalline solar cell is Now, it is standard to make a solar module which can give 15 V open-circuit voltage at any condition.
Hence, the required number of solar cells to construct such solar module is, So, 36 numbers of crystalline solar cells are required to build a standard solar module of 15 V.
COST ESTIMATION
Plant Capacity 304 Nos/Day
Land & Building (4000 sq.mt.) Rs. 2.58 Cr
Plant & Machinery Rs. 2.63 Cr
Working Capital for 2 Months Rs. 10.78 Cr
Total Capital Investment Rs. 16.39 Cr
Rate of Return 13%
Break Even Point 76%
- INTRODUCTION
- CONSTRUCTION OF PV MODULE
- THE 6 MAIN COMPONENTS OF A SOLAR PANEL
- PV CELLS
- A MONOCRYSTALLINE SOLAR CELL (CLICK TO ENLARGE)
- GLASS
- FRAME
- EVA FILM
- BACKSHEET
- JUNCTION BOX
- BYPASS DIODES
- NUMBER OF CELLS IN MODULE
- SOLAR PV MODULE SPECIFICATION
- (A) MECHANICAL SPECIFICATION
- (B) ELECTRICAL SPECIFICATION
- TYPES OF SOLAR PV MODULE
- CRYSTALLINE SILICON PV MODULE
- (I) SINGLE CRYSTALINE (MONO-CRYSTALLINE)
- CONSTRUCTION
- TECHNICAL SPECIFICATION
- ADVANTAGES OF MONOCRYSTALLINE PV MODULE
- DISADVANTAGES
- APPLICATIONS OF MONOCRYSTALLINE SOLAR PANELS
- (II) POLY-CRYSTALLINE (MULTI CRYSTALLINE)
- CONSTRUCTION
- ADVANTAGES OF POLYCRYSTALLINE PV MODULE
- DISADVANTAGES OF POLYCRYSTALLINE SOLAR PANELS
- APPLICATIONS OF POLYCRYSTALLINE SOLAR PANELS
- ADVANTAGES OF PV PANNEL
- DISADVANTAGES OF PV PANEL
- USES AND APPLICATION OF PV POWER PLANT
- APPLICATIONS OF MONOCRYSTALLINE SOLAR PANELS
- APPLICATIONS OF POLYCRYSTALLINE SOLAR PANELS
- EXAMPLES OF SOME APPLICATIONS OF PHOTOVOLTAICS ARE THE FOLLOWING:
- AGRICULTURE
- INDUSTRY, TELECOMMUNICATIONS & PUBLIC SERVICES
- HEALTH
- B.I.S. SPECIFICATION
- PROCESS FLOW CHART FOR SOLAR PANEL
- FABRICATION PROCESS OF MONOCRYSTALLINE SOLAR PV MODULE
- A. SOLAR CELL
- B. EVA (ETHYLENE VINYL ACETATE)
- ENCAPSULANT’S (EVA) REQUIREMENTS:
- C. BACK SHEET
- REQUIREMENTS OF REAR SURFACE:
- D. GLASS
- REQUIREMENTS:-
- E. JUNCTION BOX WITH BYPASS DIODES AND CONNECTING CABLES JUNCTION
- CABLES JUNCTION BOX CONSISTS OF THE FOLLOWING:-
- F. CONNECTING RIBBON TWO TYPES OF CONNECTING RIBBON ARE
- G. SILICONE SEALANT
- SEALANT
- H. SHORT AND LONG FRAMES (BACKBONE OF THE MODULE STRUCTURE)
- PLANT AND MACHINERY
- (1) CELL TESTER
- (2) TABBING & STRINGING MACHINE
- (3) LAYUP MACHINE
- (4) MODULE LAMINATOR
- (5) MODULE TESTER
- (6) LASER INSPECTION MACHINE
- MARKET POSITION
- NEW US ELECTRICITY-GENERATING CAPACITY ADDITIONS, 2010-H1 2021
- US SOLAR SYSTEM PRICING BY QUARTER, 2015-H1 2021
- MARKET SEGMENT
- RESIDENTIAL PV
- RESIDENTIAL INSTALLATIONS AND FORECAST, 2015-2026
- COMMERCIAL PV
- COMMERCIAL SOLAR INSTALLATIONS AND FORECAST, 2015-2026
- COMMUNITY SOLAR PV
- COMMUNITY SOLAR INSTALLATIONS AND FORECAST, 2015-2026
- UTILITY PV
- UTILITY PV INSTALLATIONS AND FORECAST, 2015-2026
- US SOLAR PV FORECASTS
- US PV INSTALLATION HISTORICAL DATA AND FORECAST, 2010-2026
- US PV INSTALLATIONS BY SHARE ON CAPACITY, 2010-2026
- NATIONAL SOLAR PV SYSTEM PRICING
- MODELED US NATIONAL AVERAGE SYSTEM PRICES BY MARKET SEGMENT, Q2 2020 AND Q2 2021
- PRINCIPLES OF PLANT LAYOUT
- STORAGE LAYOUT:
- EQUIPMENT LAYOUT:
- SAFETY:
- PLANT EXPANSION:
- FLOOR SPACE:
- UTILITIES SERVICING:
- BUILDING:
- MATERIAL-HANDLING EQUIPMENT:
- RAILROADS AND ROADS:
- MAJOR PROVISIONS IN ROAD PLANNING FOR MULTIPURPOSE SERVICE ARE:
- PLANT LOCATION FACTORS
- PRIMARY FACTORS
- 1. RAW-MATERIAL SUPPLY:
- 2. MARKETS:
- 3. POWER AND FUEL SUPPLY:
- 4. WATER SUPPLY:
- 5. CLIMATE:
- SPECIFIC FACTORS
- 6. TRANSPORTATION:
- A. AVAILABILITY OF VARIOUS SERVICES AND PROJECTED RATES
- 7. WASTE DISPOSAL:
- 8. LABOR:
- 9. REGULATORY LAWS:
- 10. TAXES:
- 11. SITE CHARACTERISTICS:
- 12. COMMUNITY FACTORS:
- 13. VULNERABILITY TO WARTIME ATTACK:
- 14. FLOOD AND FIRE CONTROL:
- EXPLANATION OF TERMS USED IN THE PROJECT REPORT
- 1. DEPRECIATION:
- 2. FIXED ASSETS:
- 3. WORKING CAPITAL:
- 4. BREAK-EVEN POINT:
- 5. OTHER FIXED EXPENSES:
- 6. MARGIN MONEY:
- 7. TOTAL LOAD:
- 8. LAND AREA/MAN POWER RATIO:
- PROJECT IMPLEMENTATION SCHEDULES
- INTRODUCTION
- PROJECT HANDLING
- PROJECT SCHEDULING
- PROJECT CONSTRUCTION SCHEDULE
- TIME SCHEDULE
- PLANT LAYOUT
- SUPPLIERS OF PV SOLAR PV MODULE
- SUPPLIERS OF RAW MATERIALS
- SUPPLIERS OF SOLAR CELL
- SUPPLIERS OF EVA ENCAPSULATE
- SUPPLIERS OF TEMPERED GLASS
- SUPPLIERS OF ALUMINIUM FRAMER
- SUPPLIERS OF JUNCTION BOXES
- SUPPLIERS OF SILICON GEL
- SUPPLIERS OF THERMO PLASTIC BACK SHEET
- SUPPLIERS OF COMPELETE PRODUCTION PLANT FOR PV PANEL
- SUPPLIERS OF POWER TRANSFORMER
- SUPPLIERS OF ELECTRICAL PANEL
- SUPPLIERS OF COOLING TOWER
- SUPPLIERS OF EFFLUENT TREATMENT PLANT (ETP PLANT)
- SUPPLIERS OF AIR POLLUTION CONTROL EQUIPMENTS
- SUPPLIERS OF AIR CONDITIONING EQUIPMENTS
- SUPPLIERS OF AIR COMPRESSORS
- SUPPLIERS OF PLATFORM WEIGHING MACHINE
- SUPPLIERS OF FIRE FIGHTING EQUIPMENTS
- SUPPLIERS OF ELECTRICAL MEASURING INSTRUMENTS
APPENDIX – A:
01. PLANT ECONOMICS
02. LAND & BUILDING
03. PLANT AND MACHINERY
04. OTHER FIXED ASSESTS
05. FIXED CAPITAL
06. RAW MATERIAL
07. SALARY AND WAGES
08. UTILITIES AND OVERHEADS
09. TOTAL WORKING CAPITAL
10. TOTAL CAPITAL INVESTMENT
11. COST OF PRODUCTION
12. TURN OVER/ANNUM
13. BREAK EVEN POINT
14. RESOURCES FOR FINANCE
15. INSTALMENT PAYABLE IN 5 YEARS
16. DEPRECIATION CHART FOR 5 YEARS
17. PROFIT ANALYSIS FOR 5 YEARS
18. PROJECTED BALANCE SHEET FOR (5 YEARS)
How to Make Project Report?
Detailed Project Report (DPR) includes Present Market Position and Expected Future Demand, Technology, Manufacturing Process, Investment Opportunity, Plant Economics and Project Financials. comprehensive analysis from industry covering detailed reporting and evaluates the position of the industry by providing insights to the SWOT analysis of the industry.
Each report include Plant Capacity, requirement of Land & Building, Plant & Machinery, Flow Sheet Diagram, Raw Materials detail with suppliers list, Total Capital Investment along with detailed calculation on Rate of Return, Break-Even Analysis and Profitability Analysis. The report also provides a birds eye view of the global industry with details on projected market size and then progresses to evaluate the industry in detail.
We can prepare detailed project report on any industry as per your requirement.
We can also modify the project capacity and project cost as per your requirement. If you are planning to start a business, contact us today.
Detailed Project Report (DPR) gives you access to decisive data such as:
- Market growth drivers
- Factors limiting market growth
- Current market trends
- Market structure
- Key highlights
Overview of key market forces propelling and restraining market growth:
- Up-to-date analyses of market trends and technological improvements
- Pin-point analyses of market competition dynamics to offer you a competitive edge major competitors
- An array of graphics, BEP analysis of major industry segments
- Detailed analyses of industry trends
- A well-defined technological growth with an impact-analysis
- A clear understanding of the competitive landscape and key product segments
Need Customized Project Report?
- Ask for FREE project related details with our consultant/industry expert.
- Share your specific research requirements for customized project report.
- Request for due diligence and consumer centric studies.
- Still haven't found what you're looking for? Speak to our Custom Research Team
About Engineers India Research Institute:
Our Approach
- Our research reports comprehensively cover Indian markets (can be modified as per your country), present investigation, standpoint and gauge for a time of five years*.
- The market conjectures are produced on the premise of optional research and are cross-accepted through associations with the business players
- We use dependable wellsprings of data and databases. What's more, data from such sources is handled by us and incorporated into the report
Why buy EIRI reports?
- Our project reports include detailed analysis that help to get industry Present Market Position and Expected Future Demand.
- Offer real analysis driving variables for the business and most recent business sector patterns in the business
- This report comprehends the present status of the business by clarifying a complete SWOT examination and investigation of the interest supply circumstance
- Report gives investigation and top to bottom money related correlation of real players/competitors
- The report gives gauges of key parameters which foresees the business execution