Menu
Your Cart

    Detailed Project Report on i.v. fluid manufacturing unit

    Detailed Project Report on i.v. fluid manufacturing unit
    Detailed Project Report on i.v. fluid manufacturing unit
    ₹ 0 INR
      Why Choose Us
      • More than 40 years of experience
      • Managed by expert industrial consultants
      • ISO 9001-2015 Certified
      • Registered under MSME, UAM No: DL01E0012000
      How we work
      • 24/5 Research Support
        Get your quesries resolved from an industry expert. Ask your queries before report or book purchase.
      • Custom Research Service
        Speak to the our consultant to design an exclusive study to serve your research needs.
      • Quality Assurance
        All reports are prepared by highly qualified consultants & verified by a panel of experts.
      • Information Security
        Your personal & confidential information is safe & secure.
       
      I.V. FLUID MANUFACTURING UNIT
      [CODE NO.4059]  
       
       
      Intravenous fluids, also known as intravenous solutions, are supplemental fluids used in intravenous therapy to restore or maintain normal fluid volume and electrolyte balance when the oral route is not possible. 
       
      IV fluid therapy is an efficient and effective way of supplying fluids directly into the intravascular fluid compartment, in replacing electrolyte losses, and in administering medications and blood products.
       
      STANDARD IVF & ELECTROLITES
       
      - NaCl 0.18 – 2.7%
      - Glucose 2.5 - 50%
      - Sodium Lactate (Hartmanns’s) Solution
      - Ringer Lactate
      - Water For injection
      - Sterile Water for Irrigation
      - Sodium Chloride 0.9% for irrigation
      - Sodium Chloride 0.18 – 0.45% and Glucose 4 – 10 %
      - Potassium Chloride 0.15 – 0.3% in Sodium Chloride 0.9%
      - Potassium Chloride 0.15 – 0.3% in Glucose 5%
       
      The aims of IV fluid administration should be to 
       
      Avoid dehydration 
       
      Maintain an effective circulating volume 
       
      Prevent inadequate tissue perfusion during a period when the patient is unable to achieve these goals through normal oral fluid intake 
       
      “Intravenous fluids have a range of physiologic effects and should be considered to be drugs with indications, dose ranges, cautions, and side effects.”
       
       
      The intravenous route is the fastest way to deliver medications and fluid replacement throughout the body, because they are introduced directly into the circulation. 
       
      Intravenous therapy may be used for fluid volume replacement, to correct electrolyte imbalances, to deliver medications, and for blood transfusions.
       
       
      Basic IV Setup
       
      Let's take a look at the most basic possible setup for an IV:
       
       
      The drip chamber is located just below the IV bag; inside this chamber we can see the fluid drip down from the bag into the IV tubing. This is where we measure the speed of a manual IV setup; we look at this chamber and count the number of drops we see per minute. So, for example, if we count 25 drops over the period of 60 seconds, we would say that the IV is infusing at a rate of 25 drops per minute, or 25 gtt/min. (In reality, we may not count the number of drops in a full minute; we can, for example, count the number of drops we see over a period of 15 seconds, and then multiply that number by 4 to get the number of drops in a full minute.)
       
      The drip chamber must always be half full. If the drip chamber is too full, we will not be able to see the drops to count them, and so we will be unable to determine the rate at which the IV is infusing. If the drip chamber is not full enough, then this will allow air to get into the IV tubing, which means that air would get into the patient's circulatory system, which could be very dangerous, blocking a blood vessel or stopping the heart.
       
      The roller clamp is what we use to control the rate at which the IV fluid infuses. If we roll it one way, it squeezes the IV tubing more tightly, making it more narrow and therefore making the fluid flow through the tubing more slowly; if we roll it the other way, it loosens its pinching of the IV tubing, making the tubing less narrow, and allowing the IV fluid to flow through at a faster rate. So, if for example, we observe (by looking at the drip chamber and counting drops) that an IV is infusing at a rate of 50 gtt/min, but it was ordered to infuse at a rate of 30 gtt/min, we would tighten the roller clamp to slow the drip rate down until we could count only 30 drops going through the drip chamber each minute.
       
      All roller clamps on a set of IV tubing should be closed before we attach a bag of IV fluid to the top of the tubing; this ensures that no air gets into the tubing.
       
      Every IV medication will be ordered to infuse at a specific rate, and one of the major tasks of hosptial nurses is to set up the IV so that it infuses at this rate and to adjust the IV periodically if the rate has changed so that it remmains at the ordered rate. The rate at which an IV fluid infuses is referred to as the IV infusion rate or flow rate.
       
      The slide clamp is used when we want to completely stop the IV from flowing, without having to adjust the roller clamp. This is handy if we want to stop the IV for a moment, but we don't want to have to reset the flow rate by readjusting the roller clamp all over again once we start the IV up again. This works by pinching the tubing completely shut when we slide the tubing into the narrowest part of the clamp.
       
      The injection port is a place where medicine or fluids other than those in the current IV bag can be injected so that they will infuse into the patient's vein through the IV tubing. On the photo above we can see two ports: one on the IV bag itself and one below the drip chamber. There is also usually an injection port close to where the needle goes into the patient's vein; we'll see this below. The injection port on the actual IV bag is used if we want to mix some kind of medication with the fluid that is in the IV bag; if we inject the medication into this port and then roll the bag a little to mix the medication into the fluid in the bag, then the patient will recieve both the medication and the IV fluid at the same time. However, this can only be done when the IV fluid and the medication are allowed to be mixed. If we want to inject medication or a second kind of IV fluid directly so that it does not mix with the IV fluid that we've already attached, then we will use one of the ports that are located below the drip chamber.
       
      COST ESTIMATION
       
       
      Plant Capacity            48,000 Nos/Day  
      Land & Building (2000 sq.mt.)  Rs. 1.68 Cr    
      Plant & Machinery                    Rs. 34.64 Cr 
      Working Capital for 1 Month    Rs. 42 Lac
      Total Capital Investment          Rs. 37.03 Cr 
      Rate of Return                          22%
      Break Even Point                      62%
       
       
      INTRODUCTION
      STANDARD IVF & ELECTROLITES
      THE AIMS OF IV FLUID ADMINISTRATION SHOULD BE TO
      BASIC IV SETUP
      TYPES OF IV FLUIDS
      CRYSTALLOIDS
      GENERAL CHARACTERISTICS OF CRYSTALLOID
      ISOTONIC IV FLUIDS
      0.9% NACL (NORMAL SALINE SOLUTION, NSS)
      DEXTROSE 5% IN WATER (D5W)
      LACTATED RINGER’S 5% DEXTROSE IN WATER (D5LRS)
      RINGER’S SOLUTION
      HYPOTONIC IV FLUIDS
      0.45% SODIUM CHLORIDE (0.45% NACL)
      0.33% SODIUM CHLORIDE (0.33% NACL)
      0.225% SODIUM CHLORIDE (0.225% NACL)
      2.5% DEXTROSE IN WATER (D2.5W)
      HYPERTONIC IV FLUIDS
      HYPERTONIC DEXTROSE SOLUTIONS
      DEXTROSE 10% IN WATER (D10W)
      DEXTROSE 20% IN WATER (D20W)
      DEXTROSE 50% IN WATER (D50W)
      NURSING CONSIDERATIONS FOR HYPERTONIC SOLUTIONS
      DARROW’S SOLUTION
      COLLOIDS
      HUMAN ALBUMIN
      DEXTRANS
      LOW-MOLECULAR-WEIGHT DEXTRANS (LMWD)
      HIGH-MOLECULAR-WEIGHT DEXTRANS (HMWD)
      IV FLUID/ELECTROLYTE THERAPY
      NORMAL SALINE
      VOLUME EFFECTS OF NS
      RINGER'S FLUIDS
      ADVANTAGE:
      DEXTROSE SOLUTIONS
      EFFECT OF DEXTROSE IN FLUID:
      VOLUME EFFECTS
      5%D
       DNS
      5 % DEXTROSE COMPOSITION:
      DEXTROSE WITH HALF STRENGTH SALINE
      ISOLYTE G,M,P,E
      PARACETAMOL 10 MG/ML SOLUTION COMPOSITION
      METRONIDAZOLE IV SOLUTION
      ECONOMIC PROFILE
      MARKET SURVEY
      APPLICATION INSIGHTS
      VOLUME INSIGHTS
      INDIA LARGE VOLUME PARENTERAL (LVP) MARKET SHARE INSIGHTS
      NORTH AMERICA AT THE FOREFRONT OF THE GLOBAL INTRAVENOUS 
          (IV) SOLUTION MARKET
      AFRICA’S PHARMACEUTICAL MARKET
      BUSINESS JUSTIFICATION
      PRODUCTS
      WHY NIGERIA?
      GLOBAL INTRAVENOUS SOLUTION MARKET: KEY TRENDS
      GLOBAL INTRAVENOUS SOLUTION MARKET: SEGMENTATION
      GLOBAL INTRAVENOUS SOLUTION MARKET: REGIONAL ANALYSIS
      GLOBAL INTRAVENOUS SOLUTION MARKET: COMPETITIVE LANDSCAPE
      MAJOR FIVE IV FLUID MONITORING DEVICES COMPANIES:
      B. BRAUN MELSUNGEN AG
      BAXTER INTERNATIONAL INC.
      BECTON, DICKINSON AND CO.
      FORTIVE CORP.
      ICU MEDICAL INC.
      SOURCE OF MACHINES TECHNOLOGY
      USES AND APPLICATION
      SOME GENERAL INTRAVENOUS FLUIDS
      SPECIFICATION OF INDIAN PHARMACOPEIA ON I.V FLUIDS 
          DEXTRAN 40 INJECTION
      DEXTRAN 110 INJECTIONS
      SODIUM CHLORIDE AND DEXTROSE INJECTION
      IDENTIFICATION:-
      ASSAY:
      BASIC RAW MATERIALS
      REQUIREMENTS OF RAW MATERIALS AND SPECIFICATIONS
      WATER FOR INJECTION
      HDPE PHARMA GRADE LAMINATE/ PLASTIC ROLL
      LABELING
      IDENTIFICATION
      HEAVY METALS
      COMPOSITION OF IV FLUID
      COMPOSITION OF COMMON IV FLUID (MEQ/L)
      COMPOSITION OF IV FLUIDS
      COMPOSITION OF COMMERCIAL I.V. FLUID AVAILABLE
      FORM FILL SEAL TECHNOLOGY
      1. FORM-FILL-SEAL TECHNOLOGY:-
      1.3. TERMINALLY STERILIZED PRODUCTS.-
      1.5 FILTRATION (MEMBRANE):-
      1.7. STERILIZATION (BY DRY HEAT):-
      LIST OF MACHINERY IV BAG PRODUCTION FORM FILL AND SEAL MACHINE
      IV BAG PRODUCTION (IV PRODUCTION AND PACKING)
      1.  WATER PURIFYING
      2.  DISTILLATION
      3.  SOLUTION FILLING
      4.  STERILIZATION
      5.  PACKING
      A TYPICAL FFS PROCESS WORKS AS FOLLOWS.
      BASIC OF BFS TECHNOLOGY
      BLOW FILL SEAL EQUIPMENT
      BFS MOLDS AND TOOLING
      BFS TRIALS
      PROCESS
      1. BLOW MOLDING
      2. FILLING
      3. SEALING
      BLOW FILL SEAL MACHINES
      BLOW FILL SEAL IS SUITABLE FOR YOUR APPLICATION:
      ASEPTIC PACKAGING
      BLOW FILL SEAL (BFS) AND FORM FILL SEAL (FFS) TECHNOLOGY
      MANUFACTURING PROCESS OF I.V. FLUID
      PROCESS IN DETAILS
      1. DISTILLED WATER PREPARATION:-
      2. SOLUTION PREPARATION:-
      3. INJECTION BLOW MOULDING
      4. MOULDING PROCESS
      5. FILLING PROCESS
      6. SEALING PROCESS
      7. MOULD OPENING PROCESS
      FILTRATION AND FILLING:-
      STERILIZATION:-
      QUALITY CONTROL:-
      THE WHOLE PROCESS CONSISTS OF THE FOLLOWING STEPS:-
      PROCESS FLOW DIAGRAM
      FLOW DIAGRAM OF MANUFACTURING OF I.V. FLUIDS
      SUPPLIERS OF RAW MATERIALS
      POTASSIUM PERMANGANATE
      SODIUM CHLORIDE (I.P. GRADE)
      DEXTROSE
      SUPPLIERS OF PLANT AND MACHINERY
      STERILIZING EQUIPMENTS
      PM METER
      LABELING MACHINES
      TANKS
      BOILER
      FILTER PRESS
      LABORATORY EQUIPMENTS
      MIXER
      RAW MATERIAL SUPPLIER
      SODIUM LACTATE     
      NACL
      KCL
      CACL2
      PRODUCT PHOTOGRAPHS
      MACHINERY PHOTOGRAPHS
      MULTIPLE EFFECT WATER DISTILLATION PLANT
      MIXER
      STORAGE VESSEL
      BLOW FILL SEAL MACHINE
      AUTOMATIC BOTTLE LABELLING MACHINES
       
       
      APPENDIX – A:
       
      01. PLANT ECONOMICS
      02. LAND & BUILDING
      03. PLANT AND MACHINERY
      04. OTHER FIXED ASSESTS
      05. FIXED CAPITAL
      06. RAW MATERIAL
      07. SALARY AND WAGES
      08. UTILITIES AND OVERHEADS
      09. TOTAL WORKING CAPITAL
      10. TOTAL CAPITAL INVESTMENT
      11. COST OF PRODUCTION
      12. TURN OVER/ANNUM
      13. BREAK EVEN POINT
      14. RESOURCES FOR FINANCE
      15. INSTALMENT PAYABLE IN 5 YEARS
      16. DEPRECIATION CHART FOR 5 YEARS
      17. PROFIT ANALYSIS FOR 5 YEARS
      18. PROJECTED BALANCE SHEET FOR (5 YEARS)
       

      How to Make Project Report?

      Detailed Project Report (DPR) includes Present Market Position and Expected Future Demand, Technology, Manufacturing Process, Investment Opportunity, Plant Economics and Project Financials. comprehensive analysis from industry covering detailed reporting and evaluates the position of the industry by providing insights to the SWOT analysis of the industry.

      Each report include Plant Capacity, requirement of Land & Building, Plant & Machinery, Flow Sheet Diagram, Raw Materials detail with suppliers list, Total Capital Investment along with detailed calculation on Rate of Return, Break-Even Analysis and Profitability Analysis. The report also provides a birds eye view of the global industry with details on projected market size and then progresses to evaluate the industry in detail.

      We can prepare detailed project report on any industry as per your requirement. 

      We can also modify the project capacity and project cost as per your requirement. If you are planning to start a business, contact us today.

      Detailed Project Report (DPR) gives you access to decisive data such as:

      • Market growth drivers
      • Factors limiting market growth
      • Current market trends
      • Market structure
      • Key highlights

      Overview of key market forces propelling and restraining market growth:

      • Up-to-date analyses of market trends and technological improvements
      • Pin-point analyses of market competition dynamics to offer you a competitive edge major competitors
      • An array of graphics, BEP analysis of major industry segments
      • Detailed analyses of industry trends
      • A well-defined technological growth with an impact-analysis
      • A clear understanding of the competitive landscape and key product segments

      Need Customized Project Report?

      1. Ask for FREE project related details with our consultant/industry expert.
      2. Share your specific research requirements for customized project report.
      3. Request for due diligence and consumer centric studies.
      4. Still haven't found what you're looking for? Speak to our Custom Research Team

      About Engineers India Research Institute:

      EIRI Board is a single destination for all the industry, company and country reports. We feature large repository of latest industry reports, leading and niche company profiles, and market statistics prepared by highly qualified consultants and verified by a panel of experts.

      Note: We can also prepare project report on any subject based on your requirement and country. If you need, we can modify the project capacity and project cost based on your requirement.

      Our reports provide an expansive market analysis of the sector by covering areas like growth drivers, trends prevailing in the industry as well as comprehensive SWOT analysis of the sector.

      Our Approach

      • Our research reports comprehensively cover Indian markets (can be modified as per your country), present investigation, standpoint and gauge for a time of five years*.
      • The market conjectures are produced on the premise of optional research and are cross-accepted through associations with the business players
      • We use dependable wellsprings of data and databases. What's more, data from such sources is handled by us and incorporated into the report

      Why buy EIRI reports?

      1. Our project reports include detailed analysis that help to get industry Present Market Position and Expected Future Demand.
      2. Offer real analysis driving variables for the business and most recent business sector patterns in the business
      3. This report comprehends the present status of the business by clarifying a complete SWOT examination and investigation of the interest supply circumstance
      4. Report gives investigation and top to bottom money related correlation of real players/competitors
      5. The report gives gauges of key parameters which foresees the business execution